Reliability results for high-efficiency foil-based back-contact PV modules
conference paper
In this paper we have presented an overview of the recent reliability results obtained at ECN for foil-based p-MWT, and novel high-efficiency n-MWT and IBC back-contact modules. As deduced from extensive TC and DH testing on p-MWT modules, two alternative low-cost conductive back sheet foils were shown to improve the module reliability. Exposure to DH of the foil-based modules can cause Cu discoloration. This is observed for EVA and a number of alternative encapsulants, with moisture ingress and some specific interactions between encapsulant and Cu substrate playing a role. The n-MWT modules showed improved resistance to DH exposure as compared to n-Pasha (front-to-back tabbing) modules. TC300 and DH2000 tests were passed for frameless IBC Mercury 2x2 modules built using standard foil-based module manufacture process and standard module materials.
-
TNO Identifier
822097
Publisher
ECN
Collation
4 p.
Place of publication
Petten
Pages
4 p.