Structural response of aluminium T-stub connections at elevated temperatures and fire
article
Many aluminium structures contain welded and bolted connections that are modeled as one or more equivalent T-stubs – also referred to as tension zone components – for the structural assessment. Knowledge on the structural behavior of such T-stubs is thus essential for proper designs. However, this behavior has never been checked for fire conditions. In this paper, the
structural behavior of aluminium T-stubs exposed to fire is studied through a combination of tests, finite element simulations, and theoretical models. A safe and conservative assessment procedure is developed for determining the critical temperature, based on the material deterioration as a function of temperature. This enables engineers and practitioners to determine a conservative value of the fire resistance.
structural behavior of aluminium T-stubs exposed to fire is studied through a combination of tests, finite element simulations, and theoretical models. A safe and conservative assessment procedure is developed for determining the critical temperature, based on the material deterioration as a function of temperature. This enables engineers and practitioners to determine a conservative value of the fire resistance.
TNO Identifier
573567
Source
Key Engineering Materials, 710, pp. 127-136.
Pages
127-136
Files
To receive the publication files, please send an e-mail request to TNO Repository.