Comparison of three different physiological wristband sensor systems and their applicability for resilience-and work load monitoring

conference paper
Leveraging miniaturized sensor and monitoring technology integrated in easy-to-wear wristband wearables represents a great opportunity for advancing Resilience and Mental Health of e.g. employees that experience high workload. Therefore, it is important to gain insights into the reliability of such technology before far reaching conclusions can be drawn and interventions can be developed. To that aim, we tested three wearable wristband sensor systems (Apple Watch, Microsoft Band and Fitbit Surge) and compared the assessed sensor output with a reliable ground truth. The results showed that heart rate, steps and distance varies considerably around the ground truth during tasks that required body movement. However, during the rest condition (sitting on chair) the heart rate was considered more reliable. It is concluded that caution is warranted while using and interpreting physiological data assessed by the new technology, but, in rest (e.g. pauses, sleep) the wearable sensors could be used to detect undesirable physiological patterns, indicative of threats to resilience or (mental) health.
TNO Identifier
572384
ISBN
9781509030873
Source
13th Annual Body Sensor Networks Conference, BSN 2016, 14-17 June 2016, San Francisco, CA, USA, pp. 272-276.
Publisher
Institute of Electrical and Electronics Engineers IEEE
Article nr.
7516272
Collation
5 p.
Pages
272-276
Files
To receive the publication files, please send an e-mail request to TNO Repository.