Concentrated aqueous piperazine as CO2 capture solvent: detailed evaluation of the integration with a power plant

conference paper
An integrated energetic evaluation has been performed of a reference coal-fired power plant, a power plant with an advanced MEA-based post-combustion CO2 capture plant, and a power plant with a capture plant using concentrated piperazine (PZ) and high-pressure flash regeneration. This comparison shows that using a MEA-based capture plant reduces the net electric efficiency from 44.6% to 35.5%, while the PZ-based capture plant reduces it to 37.4%, corresponding to an efficiency penalty of only 7.2%.
TNO Identifier
523224
ISSN
18766102
Publisher
Elsevier
Source title
Energy Procedia
Editor(s)
Dixon, T.
Twinning, S.
Herzog, H.
Place of publication
Amsterdam
Pages
1218-1222