A tactile P300 BCI and the optimal number of tactors : Effects of target probability and discriminability
conference paper
For P300 based BCIs, tactile stimuli are potentially more suitable than visual or auditory ones, since the do not occupy the visual or auditory channel and they can be delivered to the user without being noticed by others. In this study, we investigate whether a BCI controlled by EEG responses to vibro-tactile stimuli around the waist is feasible. In addition, we explore the effect of varying the number of (equally spaced) tactors: whereas a large number of tactors is expected to enhance the P300 since the target will be more seldom, it could negatively affect the P300 since the shorter distance between the tactors will make it more difficult to discriminate between targets and distracters. Subjects were asked to attend to the vibrations of a (varying) target tactor, embedded within distracters. The number of tactors could be two, four or six. We demonstrated a functioning tactile P300 BCI. Although the P300 in the condition with two tactors (where target and distracter were equally often presented) was smaller compared to the other conditions, we did not find a difference in SWLDA classification performance between the different numbers of tactors.
Topics
TNO Identifier
22162
Source title
4th international brain-computer interface workshop 30 april 2008