Searched for: subject%3A%22humidity%22
(1 - 20 of 63)

Pages

document
Cheng, Z. (author), Zhang, J. (author), Yu, B. (author), Chappell, N.A. (author), van Meerveld, H.J. (author), Bruijnzeel, L.A. (author)
Predicting catchment stormflow responses after tropical deforestation remains difficult. We used 5-min rainfall and storm runoff data for 30 events to calibrate the Green-Ampt (GA) and the Spatially Variable Infiltration (SVI) models and predict runoff responses for a small, degraded grassland catchment on Leyte Island (the Philippines), where...
article 2023
document
Loomans, M. (author), Kompatscher, K. (author), Huisman, E. (author), Kort, H. (author), Maassen, W. (author), Traversari, A.A.L. (author)
Humidification is not a common procedure in many buildings in the Netherlands. An exception are buildings used for healthcare, especially hospitals. There, e.g. in operating theatres, relative humidity (RH) generally is controlled stringently at levels around 50%. From an energy point-of-view humidification is an energy-intensive activity....
conference paper 2022
document
Ansaloni, L. (author), Saric, M. (author), Lauradour, E. (author), Radmanesh, F. (author), Dijkstra, J.W. (author), Pilz, M. (author), Hovik, D. (author), Benes, N.E. (author), van Delft, Y. (author), Peters, T.A. (author)
In the present work, the high-temperature and long-term hydrothermal stability of novel polyPOSS-imide membranes for high-temperature hydrogen separation is investigated. The polyPOSS-imide membranes are found to exhibit an appropriate stability up to 300 C. Above this temperature the membrane selectivity rapidly decreases, which is seemingly...
article 2022
document
Ruijten, P. (author), Huinink, H.P. (author), Adan, O.C.G. (author)
article 2021
document
Ansaloni, L. (author), Sarić, M. (author), Louradour, E. (author), Radmanesh, F. (author), Dijkstra, J.W. (author), Pilz, M. (author), Høvik, D. (author), Benes, N.E. (author), van Delft, Y. (author), Peters, T.A. (author)
In the present work, the high-temperature and long-term hydrothermal stability of novel polyPOSS-imide membranes for high-temperature hydrogen separation is investigated. The polyPOSS-imide membranes are found to exhibit an appropriate stability up to 300 °C. Above this temperature the membrane selectivity rapidly decreases, which is seemingly...
article 2021
document
Ruijten, P. (author), Huinink, H.P. (author), Adan, O.C.G. (author)
Fungal growth often appears in a surrounding where water and nutrients are scarce. The impact of this environment during sporogenesis on subsequent growth is often neglected.This study investigates the effect of water availability during sporogenesis on subsequent early growth. Therefore, a carbon-depleted substrate was constructed. Humidity is...
article 2020
document
Gerrett, N. (author), Kingma, B.R.M. (author), Sluijter, R. (author), Daanen, H.A.M. (author)
The Tokyo Olympics and Paralympic games in 2020 will be held in hot and humid conditions. Heat acclimation (in a climatic chamber) or heat acclimatization (natural environment) is essential to prepare the (endurance) athletes and reduce the performance loss associated with work in the heat. Based on the 1990-2018 hourly meteorological data of...
article 2019
document
Sprung, D. (author), Sucher, E. (author), Grossmann, P. (author), Kociok, T. (author), van Eijk, A.M.J. (author), Stein, K. (author)
conference paper 2019
document
Theelen, M.J. (author), de Graaf, F. (author), Daume, F. (author), Barreau, N. (author), Vroon, Z.A.E.P. (author), Zeman, M. (author)
Degradation rates and mechanisms for molybdenum back contacts and ZnO:Al front contacts exposed to damp heat were obtained from literature and experiments. It was found that molybdenum back contacts with a higher density and covered by a MoSe2 film are more stable than their low density, bare counterparts. For ZnO:Al front contacts various...
conference paper 2018
document
Theelen, M. (author), Beyeler, K. (author), Steijvers, H. (author), Barreau, N. (author)
Unencapsulated CIGS solar cells were simultaneously exposed to either dry or damp heat combined illumination. In-situ monitoring of their electrical parameters demonstrated a rapid decrease of the efficiency for the solar cells exposed to damp heat plus illumination. This decrease was mainly driven by changes in the shunt resistances, affecting...
article 2017
document
Theelen, M. (author), Steijvers, H. (author), Bakker, K. (author), Vink, J. (author), Mortazavi, S. (author), Mulder, A. (author), Barreau, N. (author), Roosen, D. (author), Haverkamp, E. (author)
Two hybrid degradation setups, allowing exposure of solar cells and modules to elevated temperatures and humidity as well as illumination have been built. CIGS solar cells were placed in the degradation setups, allowing real time monitoring of their electrical properties. Under open circuit conditions, the efficiency of alkali-rich CIGS solar...
conference paper 2016
document
Theelen, M. (author), de Graaf, F. (author), Daume, F. (author), Barreau, N. (author), Vroon, Z. (author), Zeman, M. (author)
Degradation rates and mechanisms for molybdenum back contacts and ZnO:Al front contacts exposed to damp heat were obtained from literature and experiments. It was found that molybdenum back contacts with a higher density and covered by a MoSe2 film are more stable than their low density, bare counterparts. For ZnO:Al front contacts, various...
conference paper 2016
document
Ding, Y. (author), Stahlmecke, B. (author), Jiménez, A.S. (author), Tuinman, I.L. (author), Kaminski, H. (author), Kuhlbusch, T.A.J. (author), van Tongeren, M. (author), Riediker, M. (author)
Different types of aerosolization and deagglomeration testing systems exist for studying the properties of nanomaterial powders and their aerosols. However, results are dependent on the specific methods used. In order to have well-characterized aerosols, we require a better understanding of how system parameters and testing conditions influence...
article 2015
document
Daanen, H.A.M. (author), Herweijer, J.A. (author)
Elderly indoors can be subject to considerable heat strain during heat waves. We investigated if a short indoor acclimation (HA) program leads to improved resilience to heat. Although full HA takes about ten days, the main changes occur in the first days, leading to reduced heat strain with similar stress. This study investigates changes after 3...
article 2015
document
Bekker, M. (author), Erich, S.J.F. (author), Hermanns, S.P.M. (author), van Maris, M.P.F.H.L. (author), Huinink, H.P. (author), Adan, O.C.G. (author)
Fungal growth in the indoor environment can affect human health by causing allergic reactions and respiratory symptoms. In the search for a solution to prevent or limit fungal growth in the indoor environment it is important to know how parameters such as temperature, substrate, and humidity affect fungal growth. Up to now, no general accepted...
article 2015
document
Theelen, M. (author), Steijvers, H. (author), Barreau, N. (author), Buffiere, M. (author), Brammertz, G. (author), Flammini, M.G. (author), van Vugt, R.J. (author), Vroon, Z. (author), Zeman, M. (author)
A 'hybrid' degradation setup, which allows the use of humidity, temperature and illumination as loads in order to accelerate degradation of solar cells and modules, has been designed and constructed. In this setup, the current voltage output of photovoltaic samples is automatically logged and the electrical parameters are calculated. This allows...
conference paper 2015
document
Janssen, E.G.O.N. (author), Hammink, H.A.J. (author), Hendriksen, L.J.A.M. (author)
Excessive humidity is a problem in Dutch growing circumstances. A traditional solution is heating and natural ventilation. To save energy a number of energy efficient dehumidification methods are developed, like mechanical ventilation with dry outside air or a curtain of cold water droplets. In this study a new principle is designed focusing on...
article 2015
document
Atuonwu, J.C. (author), van Straten, G. (author), van Deventer, H.C. (author), van Boxtel, A.J.B. (author)
This work analyzes the synergy between two complementary unit operations - adsorbent dehumidification and drying - and presents a mixed integer nonlinear programming approach to optimize energy performance in a two-stage system. Combined with active constraint analysis, the adsorbent properties that promote energy performance are derived....
article 2013
document
Kastelein, J. (author), van der Vossen, J.M.B.M. (author)
Kimguard One-Step sterilisation wrap has regulatory approval as a Class I medical device suitable for packaging terminally sterilised medical items. In this study, we evaluated the performance of five different grades of Kimguard One-Step sterilisation wrap after prion sterilisation cycle (134 °C for 18 minutes) using the final pack test method....
article 2013
document
Vásquez Quintero, A. (author), van Remoortere, B. (author), Smits, E.C.P. (author), van den Brand, J. (author), Briand, D. (author), Schoo, H.F.M. (author), de Rooij, N.F. (author)
This paper describes and compares two integration methods to structurally laminate and interconnect foil-based components with flexible polymeric substrates. The first method uses isotropic conductive adhesives (ICA) confined in laser-ablated through foil vias (TFV), while the second one uses an anisotropic conductive adhesive (ACA). Both...
article 2013