- document
-
Jansen, J.R.C. (author), Schreuder, J.J. (author), Mulier, J.P. (author), Smith, N.T. (author), Settels, J.J. (author), Wesseling, K.H. (author), Technisch Physische Dienst TNO - TH (author)In three clinical centres, we compared a new method for measuring cardiac output with conventional thermodilution. The new method computes beat-to-beat cardiac output from radial artery pressure by simulating a three-element model of aortic input impedance, and includes non-linear aortic mechanical properties and a self-adapting systemic...article 2001
- document
-
Harms, M.P.M. (author), Wesseling, K.H. (author), Pott, F. (author), Jenstrup, M. (author), van Goudoever, J. (author), Secher, N.H. (author), van Lieshout, J.J. (author), TNO Biomedical Instrumentation (author)The relationship between aortic flow and pressure is described by a three-element model of the arterial input impedance, including continuous correction for variations in the diameter and the compliance of the aorta (Modelflow). We computed the aortic flow from arterial pressure by this model, and evaluated whether, under orthostatic stress,...article 1999
- document
-
Jansen, J.R.C. (author), Schreuder, J.J. (author), Settels, J.J. (author), Kornet, L. (author), Penn, O.C.K.M. (author), Mulder, P.G.H. (author), Versprille, A. (author), Wesseling, K.H. (author), TNO Biomedical Instrumentation (author)Application of the Stewart-Hamilton equation in the thermodilution technique requires flow to be constant. In patients in whom ventilation of the lungs is controlled, flow modulations may occur leading to large errors in the estimation of mean cardiac output. Methods: To eliminate these errors, a modified equation was developed. The resulting...article 1996
- document
-
TNO Biomedical Instrumentation (author), Wesseling, K.H. (author), Jansen, J.R.C. (author), Settels, J.J. (author), Schreuder, J.J. (author)We computed aortic flow pulsations from arterial pressure by simulating a nonlinear, time-varying three-element model of aortic input impedance. The model elements represent aortic characteristic impedance, arterial compliance, and systemic vascular resistance. Parameter values for the first two elements were computed from a published, age...article 1993
- document
-
Jansen, J.R.C. (author), Schreuder, J.J. (author), Settels, J.J. (author), Kloek, J.J. (author), Versprille, A. (author), Technisch Physische Dienst TNO - TH (author)The application of the thermodilution method in conditions associated with variations in blood flow implies a misuse of the Stewart Hamilton equation. Therefore, we studied the reliability of the thermodilution method for the estimation of mean cardiac output (CO) during mechanical ventilation in patients (n = 9). Variation of the injection...article 1990