Searched for: subject:"Determinants"
(1 - 5 of 5)
document
Gizdulich, P. (author), Wesseling, K.H. (author), TNO Biomedical Instrumentation (author)
Pressure-volume (p-V) relationships of a segment of the forearm circulation have been measured in nine male healthy subjects. Forearm volume was measured using electrical impedance plethysmography, arterial transmural pressure by subtracting mean arterial pressure measured contralaterally in a finger from the pressure in a cuff placed over the...
article 1988
document
Guelen, I. (author), Westerhof, B.E. (author), van der Sar, G.L. (author), van Montfrans, G.A. (author), Kiemeneij, F. (author), Wesseling, K.H. (author), Bos, W.J.W. (author), Gaubius Instituut TNO (author)
Objective: To evaluate three methods aimed at the reconstruction of brachial pressure from non-invasive finger arterial pressure measurements as implemented in the Finometer™, (FMS, Finapres Measurement Systems, Arnhem, Netherlands), the successor to the Finapres™ (TNO Siomedical Instrumentation, Amsterdam, Netherlands). Methods: Finger arterial...
article 2003
document
Gizdulich, P. (author), Imholz, B.P.M. (author), van den Meiracker, A.H. (author), Parati, G. (author), Wesseling, K.H. (author), TNO Biomedical Instrumentation (author)
Objective. Arterial pressure waveforms distort between brachial and finger arteries, causing differences mainly in systolic pressure. Distortion, reportedly, can be removed by applying a waveform filter to the finger pressure. Design. We analysed the data from two studies that detected discrepancies in systolic tracking between Finapres and...
article 1996
document
Jellema, W.T. (author), Imholz, B.P.M. (author), van Goudoever, J. (author), Wesseling, K.H. (author), van Lieshout, J.J. (author), Technisch Physische Dienst TNO - TH (author)
1. The aims of this study were to determine the clinical feasibility of continuous, non-invasive Finapres recordings as a replacement for intrabrachial pressure during a 30 min head-up tilt, and the reliability of continuous cardiac output computation by pulse contour analysis from the finger arterial versus the brachial waveform. 2. In eight...
article 1996
document
Harms, M.P.M. (author), Wesseling, K.H. (author), Pott, F. (author), Jenstrup, M. (author), van Goudoever, J. (author), Secher, N.H. (author), van Lieshout, J.J. (author), TNO Biomedical Instrumentation (author)
The relationship between aortic flow and pressure is described by a three-element model of the arterial input impedance, including continuous correction for variations in the diameter and the compliance of the aorta (Modelflow). We computed the aortic flow from arterial pressure by this model, and evaluated whether, under orthostatic stress,...
article 1999
Searched for: subject:"Determinants"
(1 - 5 of 5)