- document
-
Polder, R.B. (author), Leggedoor, J. (author), Schuten, G. (author), Sajna, S. (author), Kranjc, A. (author), TNO Bouw en Ondergrond (author)Cathodic protection delivers corrosion protection in concrete structures exposed to aggressive environments, e.g. in de-icing salt and marine climates. Working lives of a large number of CP systems are at least more than 13 years and probably more than 25 years, provided a minimum level of maintenance is applied. This involves routine checks of...conference paper 2010
- document
-
de Vries, J. (author), Polder, R.B. (author), TNO Bouw (author)As part of the maintenance policy of the dutch Ministry of Transport, Civil Engineering Division, hydrophobic treatment of concrete was considered as an additional protective measure against penetration of aggressive substances, for instance deicing salts in bridge decks. A set of tests was designed to determine the performance of commercial...article 1997
- document
-
de Vries, J. (author), Polder, R.B. (author)As part of the maintenance policy of the Dutch Ministry of Transport, Civil Engineering Division, hydrophobic treatment of concrete was considered as an additional protective measure against penetration of aggressive substances, for instance deicing salts in bridge decks. A set of tests was designed to determine the performance of commercially...article 1996