Searched for: subject%3A%22Corrosion%255C%2Brate%22
(1 - 6 of 6)
document
Khakharia, P. (author), Mertens, J. (author), Huizinga, A. (author), de Vroey, S. (author), Sanchez Fernandez, E. (author), Srinivasan, S. (author), Vlugt, T.J.H. (author), Goetheer, E.L.V. (author)
Corrosion in amine treating plants is known to cause integrity failures, plant shutdown, costly repairs, and so forth. The use of an amine treatment system for postcombustion CO2 capture brings additional challenges in terms of the flue gas quality, flue gas composition, operating conditions, scale of operation, and so forth. These differences...
article 2015
document
Heyer, A. (author), D'Souza, F. (author), Morales, C.F.L. (author), Ferrari, G. (author), Mol, J.M.C. (author), de Wit, J.H.W. (author)
Microbiologically Influenced Corrosion (MIC) is the term used for the phenomenon in which corrosion is initiated and/or accelerated by the activities of microorganisms. MIC is a very serious problem for the ship industry as it reduces structural lifetime in combination with safety risks for crewmembers or inspection personal and increases...
article 2013
document
Pacheco, J. (author), Polder, R.B. (author), Fraaij, A.L.A. (author), Mol, J.M.C. (author)
Cathodic Protection (CP) of steel in concrete has been used over the past decades in order to increase the remaining service life of concrete infrastructure. CP involves the application of an electrical current to the corroding reinforcing bars, thus stopping and preventing further corrosion. The application of current on the reinforcing steel...
conference paper 2012
document
Polder, R.B. (author), Peelen, W.H.A. (author), Neeft, E.A.C. (author), Stoop, B.T.J. (author), TNO Bouw en Ondergrond (author)
Over the last 25 years, cathodic protection (CP) of reinforced concrete structures suffering from chloride induced reinforcement corrosion has shown to be successful and durable. CP current causes steel polarisation, electrochemical reactions and ion transport in the concrete. CP systems are designed based on experience, which results in...
article 2010
document
Polder, R.B. (author), Peelen, W.H.A. (author), Leegwater, G. (author), TNO Bouw en Ondergrond (author)
Since about 1980 Corrosion Monitoring Systems have been used in many concrete structures in aggressive environmentworldwide. While these systemswork properly in aboveground environment, some questions have arisen for submerged conditions, e.g. the outer sides of tunnels, piers in seawater or foundations in wet soil. One question concerns macro...
bookPart 2008
document
TNO Bouw (author), Polder, R.B. (author), Bertolini, L. (author)
report 1997
Searched for: subject%3A%22Corrosion%255C%2Brate%22
(1 - 6 of 6)