Finck, C.J. (author), Henquet, E.M.R. (author), van Soest, C.F.L. (author), Oversloot, H.P. (author), de Jong, A.J. (author), Cuypers, R. (author), van 't Spijker, J.C. (author) A 3 kWh thermochemical heat storage (TCS) module was built as part of an all-in house system implementation focusing on space heating application at a temperature level of 40 ºC and a temperature lift of 20 K. It has been tested and measurements showed a maximum water circuit temperature span (released by adsorption) of 20 – 51 K which is by all...
article 2014