Nieuwland, R.A. (author), Cheng, L.K. (author), Lemmen, M.H.J. (author), Oostenbrink, R.H. (author), Harmsma, P.J. (author), Schreuder, J.J. (author)
An overview of a fiber Bragg based sensor system, developed for in-vivo vascular pressure and temperature sensing, is presented. The focus is on sensor miniaturization and interrogator optimization to reach a viable sensor system.
conference paper 2014
document
Jansen, J.R.C. (author), Schreuder, J.J. (author), Mulier, J.P. (author), Smith, N.T. (author), Settels, J.J. (author), Wesseling, K.H. (author), Technisch Physische Dienst TNO - TH (author)
In three clinical centres, we compared a new method for measuring cardiac output with conventional thermodilution. The new method computes beat-to-beat cardiac output from radial artery pressure by simulating a three-element model of aortic input impedance, and includes non-linear aortic mechanical properties and a self-adapting systemic...
article 2001
document
Segers, P. (author), Stergiopulos, N. (author), Schreuder, J.J. (author), Westerhof, B.E. (author), Westerhof, N. (author)
It is generally accepted that the left ventricle (LV) hypertrophies (LVH) to normalize systolic wall stress (σ(s)) in chronic pressure overload. However, LV filling pressure (P(v)) may be elevated as well, supporting the alternative hypothesis of end-diastolic wall stress (σ(d)) normalization in LVH. We used an LV time-varying elastance model...
article 2000
document
Jansen, J.R.C. (author), Schreuder, J.J. (author), Settels, J.J. (author), Kornet, L. (author), Penn, O.C.K.M. (author), Mulder, P.G.H. (author), Versprille, A. (author), Wesseling, K.H. (author), TNO Biomedical Instrumentation (author)
Application of the Stewart-Hamilton equation in the thermodilution technique requires flow to be constant. In patients in whom ventilation of the lungs is controlled, flow modulations may occur leading to large errors in the estimation of mean cardiac output. Methods: To eliminate these errors, a modified equation was developed. The resulting...
article 1996
document
TNO Biomedical Instrumentation (author), Wesseling, K.H. (author), Jansen, J.R.C. (author), Settels, J.J. (author), Schreuder, J.J. (author)
We computed aortic flow pulsations from arterial pressure by simulating a nonlinear, time-varying three-element model of aortic input impedance. The model elements represent aortic characteristic impedance, arterial compliance, and systemic vascular resistance. Parameter values for the first two elements were computed from a published, age...
article 1993
document
Jansen, J.R.C. (author), Schreuder, J.J. (author), Settels, J.J. (author), Kloek, J.J. (author), Versprille, A. (author), Technisch Physische Dienst TNO - TH (author)
The application of the thermodilution method in conditions associated with variations in blood flow implies a misuse of the Stewart Hamilton equation. Therefore, we studied the reliability of the thermodilution method for the estimation of mean cardiac output (CO) during mechanical ventilation in patients (n = 9). Variation of the injection...
article 1990
document
Jansen, J.R.C. (author), Wesseling, K.H. (author), Settels, J.J. (author), Schreuder, J.J. (author), Technisch Physische Dienst TNO - TH (author)
Most pulse contour methods are unreliable under changing haemodynamic conditions, because no corrections are made for pressure-dependent compliance and reflections of pressure waves. The pulse contour method of Wesseling includes such corrections. Four thermodilution measurements equally spread over the ventilatory cycle were used to calibrate...
article 1990