Pages
- 1
- 2
- document
-
Frank, D. (author), Jha, N.K. (author), Koene, F.G.H. (author), Kemp, R.E.J. (author), Twerda, A. (author), Linden, P.F. (author)An air curtain is a planar turbulent air jet, which is used to separate two zones maintained at different temperatures. One of the aims of using an air curtain in the doorway of a building is to minimise the heat losses from the warm room to the cold environment and thus, to save energy. It is important to know how well an air curtain performs...article 2022
- document
-
Koene, F.G.H. (author), Eslami Mossallam, B. (author)Future energy infrastructures are expected to be smart, with the application of energy storage and demand-side management strategies. To size the energy storage and assess the flexibility of the heat demand in a district, insight into its heat demand profile is a prerequisite. A tool was developed to generate the hourly space heating demand of a...article 2022
- document
-
Matthijssen, E.F. (author), Menkveld, M. (author), Koene, F.G.H. (author), de Ridder, L.A.C. (author)In het klimaatakkoord is afgesproken dat 7 miljoen woningen en 1 miljoen utiliteitsgebouwen in 2050 geen gebruik meer maken van aardgas. Hiervoor moeten in 2030 reeds 1,5 miljoen bestaande woningen en gebouwen zijn verduurzaamd. Gemeentes hebben in hun Transitievisie Warmte uiterlijk 2021 bekend gemaakt welke opties in welke wijken en in welk...report 2022
- document
-
Koene, F.G.H. (author), Oppenoortth, M. (author), Langedijk, R. (author)This paper studies the level of improvement of building envelopes required to heat the Dutch housing stock using an energy supply without natural gas, such as a district heating network at lower supply temperature or a heat pump. We identified 35 building types to represent the Dutch housing stock of single-family dwellings. A 4R2C building...conference paper 2021
- document
-
Jacobs, P. (author), Kemp, R.E.J. (author), Koene, F.G.H. (author)Nederland streeft naar een energieneutrale gebouwde omgeving in 2050. Ook scholen moeten hieraan bijdragen. Bij de huidige energetische renovatie van scholen treedt echter een probleem op: toename van oververhitting. Dit vraagt om de ontwikkeling van energiezuinige koeltechnieken die bij renovatie toepasbaar zijn en niet of nauwelijks tot meer...report 2021
- document
-
Koene, F.G.H. (author), Oppenoorth, M. (author), Langedijk, R. (author), van der Linden, A.C. (author), Sewait, K.E. (author)De komende jaren zal de Nederlandse woningvoorraad verduurzaamd moeten worden, liefst zonder inzet van aardgas. In opdracht van de provincie Noord-Holland hebben TNO, Duurzaam Bouwloket en Regionaal Energieloket de volgende twee vragen beantwoord: 1. Welke verduurzamingsmaatregelen zijn nodig voor een aardgasvrije energievoorziening van...report 2021
- document
-
Koene, F.G.H. (author), Oppenoorth, M. (author), Langedijk, R. (author), van der Linden, K. (author), Sewalt, K.E. (author)De komende jaren zal de Nederlandse woningvoorraad verduurzaamd moeten worden en van het aardgas af moeten gaan. Er bestaat behoefte aan inzicht in de randvoorwaarden voor de Nederlandse gebouwvoorraad voor een transitie naar een nieuwe energie-infrastructuur, in het bijzonder voor vooroorlogse woningen met hun bouwkundige beperkingen voor...report 2020
- document
-
Jacobs, P. (author), Borsboom, W.A. (author), Koene, F.G.H. (author), van Haaster, S. (author), van Os, J. (author), Koppen, W. (author), Kraakman, P.H. (author)Binnenluchtkwaliteit is nog een zwakke schakel in de realisatie van energie-efficiƫnte woningen. Veelal wordt bij nieuwbouw en renovatie volstaan met de Bouwbesluit minimum ventilatie eis van 75 m3/uur afvoer voor een keuken. Op basis van metingen en simulaties wordt een afzuigkap met minimaal 83 dm3/s (300 m3/uur) aanbevolen. Dergelijke...article 2019
- document
-
Koene, F.G.H. (author), de Kluizenaar, Y. (author), Bulavskaya, T. (author), Hoes-van Oeffelen, E.C.M. (author), Spiekman, M.E. (author), Hofstetter, H. (author), Opstelten, I.J. (author)Generally, a discrepancy is observed between energy use for heating of dwellings, calculated by numerical models and actual energy use. This gap may be partially attributed to differences between assumed and actual occupant behavior. To account for the gap, a number of occupant behavioral models were made on thermostat settings, the likelihood...article 2015
- document
-
Levie, D. (author), de Kluizenaar, Y. (author), Hoes-van Oeffelen, E.C.M. (author), Hofstetter, H. (author), Janssen, S.A. (author), Spiekman, M.E. (author), Koene, F.G.H. (author)Background: Ventilation in dwellings is essential for well-being and health. However, insight in determinants of ventilation behavior is still limited. Aim: Identifying determinants of ventilation behavior and quantifying relationships. Secondly, identifying households characteristics associated with low ventilation activity. Methods: In a cross...article 2014
- document
-
Koene, F.G.H. (author), Bakker, L.G. (author), Lanceta, D. (author), Narmsara, S. (author)In the setting of this paper, a building is represented by a simple model consisting of two thermal masses. Generic values were obtained for two unknown parameters in the model, capable of representing an office building, a single family dwelling and a multifamily dwelling, at three levels of thermal insulation. The model allows the aggregation...conference paper 2014
- document
-
Koene, F.G.H. (author)Hoe kun je de energetische kwaliteitvan een individuele woning meten? Enkel het gasgebruik meten is niet voldoende, omdat de bewoner zuinig of juist niet zuinig kan stoken. Hoeveel gas is nodigvoorwarm tapwaterbereiding? Was het een strenge winter? De in dit artikel beschreven methodologie bepaalt de energetische kwaliteit met drie verschillende...article 2012
- document
-
Koene, F.G.H. (author)A methodology is presented that entails three ways to determine the heat losses of a dwelling in the heating season, each using a different set of data. The first method gives an indication of the theoretical 'energetic' quality of a dwelling, the second and third provide an indication of the actual 'energetic' quality of the dwelling. The third...conference paper 2011
- document
-
Energieonderzoek Centrum Nederland (author), Koene, F.G.H. (author), Kondratenko, I. (author)n.v.t.conference paper 2009
- document
-
Energieonderzoek Centrum Nederland (author), Koene, F.G.H. (author), Knoll, B. (author)n.v.t.conference paper 2009
- document
-
Kaan, H.F. (author), Koene, F.G.H. (author), Kondratenko, I. (author)n.v.t.conference paper 2008
- document
-
Energieonderzoek Centrum Nederland (author), Kaan, H.F. (author), Koene, F.G.H. (author), Kondratenko, I. (author)n.v.t.conference paper 2008
- document
-
Energieonderzoek Centrum Nederland (author), Koene, F.G.H. (author)n.v.t.article 2007
- document
-
Energieonderzoek Centrum Nederland (author), Kaan, H.F. (author), Koene, F.G.H. (author), Bakker, E.J. (author), Zondag, H.A. (author), Haartsen, J. (author), Brouwer, J. (author)-report 2003
- document
-
Energieonderzoek Centrum Nederland (author), Koene, F.G.H. (author), Ligthart, F.A.T.M. (author)-report 2001
Pages
- 1
- 2