document
Pokol, G.I. (author), Zoletnik, S. (author), Dunai, D. (author), Marchuk, O. (author), Baross, T. (author), Erdei, G. (author), Grunda, G. (author), Kiss, I.G. (author), Kovacsik, A. (author), von Hellermann, M. (author), Lischtschenko, O. (author), Biel, W. (author), Jaspers, R.J.E. (author), Durkut, M. (author)
The ITER core CXRS diagnostic system collects the light emitted from the interaction of the diagnostic neutral beam with the core plasma and guides it via a mirror labyrinth through the upper port plug #3 towards a fiber bundle, which then transmits the light into a set of spectrometers for spectral analysis. In order to test the accessibility...
article 2013
document
Naylor, G.A. (author), Scannell, R. (author), Beurskens, M. (author), Walsh, M.J. (author), Pastor, I. (author), Donné, A.J.H. (author), Snijders, B. (author), Biel, W. (author), Meszaros, B. (author), Giudicotti, L. (author), Pasqualotto, R. (author), Marot, L. (author)
The central electron temperature and density of the ITER plasma may be determined by Thomson scattering. A LIDAR topology is proposed in order to minimize the port access required of the ITER vacuum vessel. By using a LIDAR technique, a profile of the electron temperature and density can be determined with a resolution of about 7 cm in the...
article 2012
document
Jaspers, R.J.E. (author), Scheffer, M. (author), Kappatou, A. (author), van der Valk, N.C.J. (author), Durkut, M. (author), Snijders, B. (author), Marchuk, O. (author), Biel, W. (author), Pokol, G.I. (author), Erdei, G. (author), Zoletnik, S. (author), Dunai, D. (author)
A feasibility study for the use of core charge exchange recombination spectroscopy on ITER has shown that accurate measurements on the helium ash require a spectrometer with a high etendue of 1mm 2sr to comply with the measurement requirements [S. Tugarinov, Rev. Sci. Instrum. 74, 2075 (2003)]10.1063/1.1537443. To this purpose such an instrument...
article 2012
document
Koning, J.F. (author), Elzendoorn, B.S.Q. (author), Ronden, D.M.S. (author), Klinkhamer, J.F.F. (author), Biel, W. (author), Krasikov, Y. (author), Walker, C.I. (author)
Central, retractable tubes are proposed in several Upper Port Plugs (UPPs) designs for ITER, to enable fast exchange of specific components of diagnostics housed in these UPPs. This paper investigates into possible designs to enable the efficient handling of tubes. The feasibility of tube handling is analysed by first reviewing the designs...
article 2011
document
Krimmer, A. (author), Klinkhamer, J.F.F. (author), Biel, W. (author), Hawkes, N. (author), Kiss, G. (author), Koning, J.F. (author), Krasikov, Y. (author), Neubauer, O. (author)
The upper port #3 in ITER will be used by the core Charge Exchange Recombination Spectroscopy (core CXRS) to channel out light from the inside of the vacuum vessel. Recent research about the lifetime of the first two mirrors and changes in the upper port plug geometry initiated further investigations into possible alternative system design...
article 2011
document
Klinkhamer, J.F.F. (author), Krimmer, A. (author), Biel, W. (author), Hawkes, N. (author), Kiss, G. (author), Koning, J. (author), Krasikov, Y. (author), Neubauer, O. (author), Snijders, B. (author)
New optical configurations for the ITER core CXRS system offer the possibility of longer ducts between the first mirror and the plasma. This has led to a renewed optimization of the availability, using a simple model of the degradation of the first mirror that starts with the conditions of (a) the required measurement performance and (b) the...
article 2011
document
Biel, W. (author), Baross, T. (author), Bourauel, P. (author), Dunai, D. (author), Durkut, M. (author), Erdei, G. (author), Hawkes, N. (author), von Hellermann, M. (author), Hogenbirk, A. (author), Jaspers, R. (author), Kiss, G. (author), Klinkhamer, J.F.F. (author), Koning, J.F. (author), Kotov, V. (author), Krasikov, Y. (author), Krimmer, A. (author), Lischtschenko, O. (author), Litnovsky, A. (author), Marchuk, O. (author), Neubauer, O. (author), Offermanns, G. (author), Panin, A. (author), Patel, K. (author), Pokol, G. (author), Schrader, M. (author), Snijders, B. (author), Szabo, V. (author), van der Valk, N.J.C. (author), Voinchet, R. (author), Wolters, J. (author), Zoletnik, S. (author)
The ITER core charge exchange recombination spectroscopy (core CXRS) diagnostic system is designed to provide experimental access to various measurement quantities in the ITER core plasma such as ion densities, temperatures and velocities. The implementation of the approved CXRS diagnostic principle on ITER faces significant challenges: First, a...
article 2011
document
Krasikov, Y. (author), Baross, T. (author), Biel, W. (author), Litnovsky, A. (author), Hawkes, N. (author), Kiss, G. (author), Klinkhamer, J.F.F. (author), Koning, J.F. (author), Krimmer, A. (author), Neubauer, O. (author), Panin, A. (author)
The paper presents component concepts developed for the ITER core charge exchange recombination spectroscopy (cCXRS). They are based on the cCXRS layout of 2009, named as reference design option. It includes an outer shell, carrying a blanket shield module and a shielding cassette. The cassette, attached to the outer shell, carries secondary...
article 2011
document
von Hellermann, M.G. (author), Barnsley, R. (author), Biel, W. (author), Delabie, E. (author), Hawkes, N. (author), Jaspers, R. (author), Johnson, D. (author), Klinkhamer, J.F.F. (author), Lischtschenko, O. (author), Marchuk, O. (author), Schunke, B. (author), Singh, M.J. (author), Snijders, B. (author), Summers, H.P. (author), Thomas, D. (author), Tugarinov, S. (author), Vasu, P. (author), TNO Industrie en Techniek (author)
Since the first feasibility studies of active beam spectroscopy on ITER in 1995 the proposed diagnostic has developed into a well advanced and mature system. Substantial progress has been achieved on the physics side including comprehensive performance studies based on an advanced predictive code, which simulates active and passive features of...
article 2010
document
Sadakov, S. (author), Baross, T. (author), Biel, W. (author), Borsuk, V. (author), Hawkes, N. (author), von Hellermann, M. (author), Gille, P. (author), Kiss, G. (author), Koning, J. (author), Knaup, M. (author), Klinkhamer, J.F.F. (author), Krasikov, Yu. (author), Litnovsky, A. (author), Neubauer, O. (author), Panin, A. (author), TNO Industrie en Techniek (author)
A plug for the ITER core charge exchange recombination spectroscopy (core CXRS) is located in the upper port 3. It transfers the light emitted by interaction of plasma ions with the diagnostic neutral beam (DNB). The plug consists of a main shell, a shielding cassette and a retractable tube. The tube carries the first mirror (M1) with a shutter...
article 2009
document
Jaspers, R.J.E. (author), von Hellermann, M.G. (author), Delabie, E. (author), Boom, J.E. (author), Donné, A.J.H. (author), Biel, W. (author), Hawkes, N.C. (author), Neubauer, O. (author), Di Maio, M. (author), Sadakov, S. (author), Klinkhamer, J.F.F. (author), Snijders, B. (author), Hogenbirk, A. (author), TNO Industrie en Techniek (author)
Charge eXchange Recombination Spectroscopy (CXRS) will play a crucial role in the diagnosing of burning plasmas: items like helium ash, transport barriers, impurity content or fuel ratio can all be assessed with CXRS. In fact this is the only direct method to obtain information about the light impurity ions, such as temperature, concentrations...
conference paper 2008
document
von Hellermann, M. (author), Jaspers, R. (author), Biel, W. (author), Litnovsky, A. (author), Neubauer, O. (author), Pap, M. (author), Hawkes, N.C. (author), Marren, C. (author), Walton, B. (author), Kaschuck, Y. (author), Serov, V. (author), Tugarinov, S. (author), Vliegenthart, W.A. (author), Moddemeijer, K. (author), Walker, C. (author), Ingesson, C. (author), TNO Industrie en Techniek (author)
A status report is given on recent joint activities on the ITER CXRS and BES diagnostic package. Expected measurement performances are reviewed as well as comprehensive discussions are led on an integral approach to the implementation of Core and Edge CXRS observation periscopes. The "first mirror" location, its operational temperature,...
article 2006
Searched for: author%3A%22Biel%2C+W.%22