Title
Variability in P-Glycoprotein Inhibitory Potency (IC50) Using Various in Vitro Experimental Systems: Implications for Universal Digoxin Drug- Drug Interaction Risk Assessment Decision Criterias
Author
Bentz, J.
O'Connor, M.P.
Bednarczyk, D.
Coleman, J.
Lee, C.
Palm, J.
Pak, Y.A.
Perloff, E.S.
Reyner, E.
Balimane, P.
Brännström, M.
Chu, X.
Funk, C.
Guo, A.
Hanna, I.
Herédi-Szabó, K.
Hillgren, K.
Li, L.
Hollnack-Pusch, E.
Jamei, M.
Lin, X.
Mason, A.K.
Neuhoff, S.
Patel, A.
Podila, L.
Plise, E.
Rajaraman, G.
Salphati, L.
Sands, E.
Taub, M.E.
Taur, J.-S.
Weitz, D.
Wortelboer, H.M.
Xia, C.Q.
Xiao, G.
Yabut, J.
Yamagata, T.
Zhang, L.
Ellens, H.
Publication year
2013
Abstract
A P-glycoprotein (P-gp) IC50 working group was established with 23 participating pharmaceutical and contract research laboratories and one academic institution to assess interlaboratory variability in P-gp IC 50 determinations. Each laboratory followed its in-house protocol to determine in vitro IC50 values for 16 inhibitors using four different test systems: human colon adenocarcinoma cells (Caco-2; eleven laboratories), Madin-Darby canine kidney cells transfected with MDR1 cDNA (MDCKII-MDR1; six laboratories), and Lilly Laboratories Cells-Porcine Kidney Nr. 1 cells transfected with MDR1 cDNA (LLCPK1- MDR1; four laboratories), and membrane vesicles containing human P-glycoprotein (P-gp; five laboratories). For cell models, various equations to calculate remaining transport activity (e.g., efflux ratio, unidirectional flux, net-secretory-flux) were also evaluated. The difference in IC50 values for each of the inhibitors across all test systems and equations ranged from a minimum of 20- and 24-fold between lowest and highest IC50 values for sertraline and isradipine, to a maximum of 407- and 796-fold for telmisartan and verapamil, respectively. For telmisartan and verapamil, variability was greatly influenced by data from one laboratory in each case. Excluding these two data sets brings the range in IC50 values for telmisartan and verapamil down to 69- and 159-fold. The efflux ratiobased equation generally resulted in severalfold lower IC 50 values compared with unidirectional or net-secretory-flux equations. Statistical analysis indicated that variability in IC50 values was mainly due to interlaboratory variability, rather than an implicit systematic difference between test systems. Potential reasons for variability are discussed and the simplest, most robust experimental design for P-gp IC 50 determination proposed. The impact of these findings on drug-drug interaction risk assessment is discussed in the companion article (Ellens et al., 2013) and recommendations are provided. © 2013 by The American Society for Pharmacology.
Subject
Life
PHS - Pharmacokinetics & Human Studies
EELS - Earth, Environmental and Life Sciences
Biomedical Innovation
Biology
Healthy Living
To reference this document use:
http://resolver.tudelft.nl/uuid:de40ba57-f6e6-43f9-a972-add0da9ff716
DOI
https://doi.org/10.1124/dmd.112.050500
TNO identifier
474189
ISSN
0090-9556
Source
Drug Metabolism and Disposition, 41 (7), 1347-1366
Document type
article