Title
A proposed eye irritation testing strategy to reduce and replace in vivo studies using Bottom-Up and Top-Down approaches
Author
Scott, L.
Eskes, C.
Hoffmann, S.
Adriaens, E.
Alepée, N.
Bufo, M.
Clothier, R.
Facchini, D.
Faller, C.
Guest, R.
Harbell, J.
Hartung, T.
Kamp, H.
Varlet, B.L.
Meloni, M.
McNamee, P.
Osborne, R.
Pape, W.
Pfannenbecker, U.
Prinsen, M.
Seaman, C.
Spielmann, H.
Stokes, W.
Trouba, K.
Berghe, C.V.d.
Goethem, F.V.
Vassallo, M.
Vinardell, P.
Zuang, V.
TNO Kwaliteit van Leven
Publication year
2010
Abstract
In spite of over 20 years of effort, no single in vitro assay has been developed and validated as a full regulatory replacement for the Draize Eye Irritation test. However, companies have been using in vitro methods to screen new formulations and in some cases as their primary assessment of eye irritation potential for many years. The present report shows the outcome of an Expert Meeting convened by the European Centre for the Validation of Alternative Methods in February 2005 to identify test strategies for eye irritation. In this workshop test developers/users were requested to nominate methods to be considered as a basis for the identification of such testing strategies. Assays were evaluated and categorized based on their proposed applicability domains (e.g., categories of irritation severity, modes of action, chemical class, physicochemical compatibility). The analyses were based on the data developed from current practice and published studies, the ability to predict depth of injury (within the applicable range of severity), modes of action that could be addressed and compatibility with different physiochemical forms. The difficulty in predicting the middle category of irritancy (e.g. R36, GHS Categories 2A and 2B) was recognized. The testing scheme proposes using a Bottom-Up (begin with using test methods that can accurately identify non-irritants) or Top-Down (begin with using test methods that can accurately identify severe irritants) progression of in vitro tests (based on expected irritancy). Irrespective of the starting point, the approach would identify non-irritants and severe irritants, leaving all others to the (mild/moderate) irritant GHS 2/R36 categories. © 2009 Elsevier Ltd.
Subject
Biology
Alternatives
In vitro tests
Ocular irritation
To reference this document use:
http://resolver.tudelft.nl/uuid:c21faa16-81b8-4b73-b809-6c7f666b075b
DOI
https://doi.org/10.1016/j.tiv.2009.05.019
TNO identifier
272836
ISSN
0887-2333
Source
Toxicology in Vitro, 24 (1), 1-9
Document type
article